Abstract
Separation of protein mixtures by batch and semi-continuous parametric pumping has been examined experimentally. The parapump used generally consist of two columns and four reservoirs. The upper column was packed with an anion exchanger (DEAE-Sepharose) and the lower one with a cation exchanger (CM-Sepharose). There was one top , two middle and one bottom reservoir , with pH equal to P2,P1,P3 and P2 respectively.
Separation was compared experimentally for the system of He/moglobin-Albumin-CM-Sepharose and DEAE-Sepharose. The results indicate that the two-column parapump has a much higher separation capability than a one-column unit. Separation factors as large as thirty-two were readily attained in the batch system.
Recommended Citation
Varuntanya, Chirasakdi, "pH parametric pumping : separation of proteins (an experimental study)" (1982). Theses. 3685.