Document Type

Thesis

Date of Award

Spring 5-31-2015

Degree Name

Master of Science in Pharmaceutical Engineering - (M.S.)

Department

Chemical, Biological and Pharmaceutical Engineering

First Advisor

Piero M. Armenante

Second Advisor

Robert Benedict Barat

Third Advisor

Laurent Simon

Abstract

Angled-mounted impellers are commonly used in a number of pharmaceutical industry applications, from laboratory reactors to full-scale tanks. In these systems, the impeller is not centrally and vertically mounted, as in most stirred vessels, but it enters the vessel, and is therefore immersed in the fluid, at an angle from the vertical. This arrangement provides some baffling effects that would not otherwise exist if the impeller was centrally mounted.

One common requirement for such systems is that they are capable of suspending small solids dispersed in the liquid. Therefore, it is critical to know the value of the minimum agitation speed at which solids become just suspended,Njs. Despite their common use in industry, and especially the pharmaceutical industry, these systems have received little attention in the literature in general and as far as their ability to solid suspension is concerned in particular.

Therefore, the focus of this work was to determine under what conditions fine divided solids become suspended in a liquid-filled, unbaffled stirred vessel provided with angled-mounted impellers. A small laboratory vessel with a hemispherical bottom was used here. Different types of axial and radial impellers mounted at different angles (0°, 5° and 10°) at different off-bottom impeller clearances were tested. The value ofNjs was experimentally obtained by visually inspecting the tank bottom and determining the impeller agitation speed at which the solids were observed to rest on the tank bottom for no more than 1-2 seconds before being swept away. In addition, a novel observer-independent criterion was developed, relying on the experimental determination of the fraction of solids remaining on the vessel bottom at increasing agitation speeds. This approach results in values ofNjs that are close agreement with the visually determined Njs values.

This approach was used to determineNjs for different impellers under a number of operating conditions. In general, mounting the impeller at an angle resulted inNjsvalues lower than those obtained with centrally mounted impellers. In addition, it was found that lower impeller clearances resulted in lowerNjs values, although the minimum for Njs was obtained when the impeller clearance was about 20% of the vessel diameter.

The results obtained in this work are expected to be applicable to a number of systems currently used in the pharmaceutical industry.

Share

COinS
 
 

To view the content in your browser, please download Adobe Reader or, alternately,
you may Download the file to your hard drive.

NOTE: The latest versions of Adobe Reader do not support viewing PDF files within Firefox on Mac OS and if you are using a modern (Intel) Mac, there is no official plugin for viewing PDF files within the browser window.