Airborne asbestos levels in several school buildings before and after bulk asbestos removal
Document Type
Article
Publication Date
11-1-1982
Abstract
Airborne particulate samples were collected in several public schools before and after friable asbestos containing (5–20 percent) insulation material had been removed from the ceiling areas. Transmission electron microscopy with selected area electron diffraction (SAED) was used for fiber identification and counting. Asbestos fiber concentrations in the air were in the range 5–40 ng/M3 before removal of the friable asbestos ceiling insulation. The airborne asbestos concentrations approximately one week after removal showed reductions of 56 to 90 percent. © Gordon and Breach Science Publishers, Inc., 1982 Printed in the United Kingdom
Identifier
0020330841 (Scopus)
Publication Title
International Journal of Environmental Studies
External Full Text Location
https://doi.org/10.1080/00207238208710010
e-ISSN
10290400
ISSN
00207233
First Page
27
Last Page
30
Issue
1
Volume
20
Recommended Citation
Bozzelli, Joseph W. and Russell, Joel F., "Airborne asbestos levels in several school buildings before and after bulk asbestos removal" (1982). Faculty Publications. 21332.