Programming a minicomputer for liquid level control in a water tank

Document Type

Article

Publication Date

10-1-1986

Abstract

A Fortran program for liquid level control in a water tank is presented in this paper. At short sampling time, a first order system adequately describes the process. At longer sampling periods the closed loop system response shows overshoot and oscillations. A first order system with a delay time of 2.0 seconds for the process, can predict such a behaviour. © 1986, Taylor & Francis Group, LLC. All rights reserved.

Identifier

0022929683 (Scopus)

Publication Title

Journal of Environmental Science and Health Part A Environmental Science and Engineering

External Full Text Location

https://doi.org/10.1080/10934528609375317

ISSN

03601226

First Page

625

Last Page

637