Document Type
Dissertation
Date of Award
8-31-2016
Degree Name
Doctor of Philosophy in Biomedical Engineering - (Ph.D.)
Department
Biomedical Engineering
First Advisor
Raquel Perez-Castillejos
Second Advisor
Treena Livingston Arinzeh
Third Advisor
Kabilan Velliyagounder
Fourth Advisor
Michael Jaffe
Fifth Advisor
Pranela Rameshwar
Abstract
Lab-on-a-chip (LOC) is a device that integrates one or more laboratory functions in a single chip with dimensions ranging from a micrometer to a few millimeters. On-chip optofluidics, which combines microfluidics and tunable micro-optical components, is crucial for bio-sensing applications. However, recently reported optofluidic devices have only two-dimensional (2D) dielectric or metallic regions for sensing cellular activity, which fail to mimic the three-dimensional (3D) in vivo microenvironment of cells.
In this research, a 3D hydrogel-based micro-scale-tissue-analog-chip (µTAC) is fabricated with an integrated optofluidic design for biomedical applications. These 3D hydrogels act as a scaffold for the cellular studies and as a waveguide for increasing the signal efficiency in sensing applications. These 3D waveguides, embedded in a Poly(dimethylsiloxane) elastomer-based optofluidic channel, are composed of Poly(ethylene glycol)-diacrylates (PEGDA). The refractive index of the PEGDA waveguides is higher compared to the water-based cladding that surrounds the waveguide. Because of this refractive index difference, waveguides confine the light waves due to the total-internal-reflection phenomenon (TIR). Initially, the characterizations and the sensing efficiency of the µTAC device are successfully demonstrated with a fluorescein detection study. This study demonstrates that the proposed device is in accordance with Beer-Lambert’s law with a limit of detection of 2.54 µM of fluorescein. Further, the sensing efficiency of the µTAC devices is tested in cellular studies by encapsulating cells inside the waveguides. Cellular studies with µTAC devices prove that the device is capable of efficiently sensing the cell density and the cell viability changes inside the waveguides with a limit of detection of ~27 cells/waveguide. In addition, this study also proves that the proposed µTAC device has a potential for long-term cell monitoring applications without compromising cell-viability. Therefore, with integrated 3D hydrogel waveguides, this µTAC-optofluidic device could be a potential platform with a broad range of applications in the fields of diagnosis and detection.
Recommended Citation
Rengarajan, Venkatakrishnan, "Fabrication of 3D hydrogel-based microscale tissue analog chip with integrated optofluidics" (2016). Dissertations. 1550.
https://digitalcommons.njit.edu/dissertations/1550