Tangent Poisson's ratio of high-strength concrete in triaxial compression
Document Type
Article
Publication Date
2-1-2007
Abstract
Based on a carefully arranged experimental programme, the paper studies the variation of the tangent Poisson's ratio of high-strength concrete with a uniaxial compressive strength of 67 MPa (100 × 200 mm cylinder) under various confining pressures in triaxial compression. It shows that the high lateral confinement can significantly reduce the initial value of the tangent Poisson's ratio as compared with that of the uniaxial compression, and the tangent Poisson's ratio at failure also decreases notably with the increase of the lateral confining pressure. Therefore the tangent Poisson's ratio of high-strength concrete depends on not only the axial stress but also the lateral confinement. A simplified expression based on the experimental results is then proposed to define this variation. The influence of cyclic loading in triaxial compression is also investigated; this shows that the lateral versus axial strain relation of high-strength concrete during the cyclic loading essentially follows the general trend of the monotonic loading.
Identifier
33846853550 (Scopus)
Publication Title
Magazine of Concrete Research
External Full Text Location
https://doi.org/10.1680/macr.2007.59.1.69
ISSN
00249831
First Page
69
Last Page
77
Issue
1
Volume
59
Recommended Citation
Lu, X. and Hsu, C. T.T., "Tangent Poisson's ratio of high-strength concrete in triaxial compression" (2007). Faculty Publications. 13549.