Dynamic condensation blocking in cryogenic refueling
Document Type
Article
Publication Date
12-12-2008
Abstract
We demonstrate that a negative feedback between vapor pressure and condensation rate may be established in two-phase systems during vapor compression with rates of practical importance. As a result, dynamic condensation blocking occurs. The effect is studied numerically in the case of filling a no-vent insulated tank by liquid hydrogen. It is shown that the filling dynamics quite sensitively depends on the filling rate, and for sufficiently fast filling rates consist of a fast stage dominated by gas compression and a slow stage governed by heat conduction in the liquid. © 2008 American Institute of Physics.
Identifier
57349141474 (Scopus)
Publication Title
Applied Physics Letters
External Full Text Location
https://doi.org/10.1063/1.3025674
ISSN
00036951
Issue
22
Volume
93
Fund Ref
National Science Foundation
Recommended Citation
Osipov, V. V. and Muratov, C. B., "Dynamic condensation blocking in cryogenic refueling" (2008). Faculty Publications. 12389.
https://digitalcommons.njit.edu/fac_pubs/12389